Carry bounds through an installation chain
A stack total alone does not show how bounded component variation can affect the final dimension. Enter each term with its algebraic sign and its absolute symmetric bound. If a term is subtracted, negate its nominal value; its uncertainty bound still adds to the worst-case span.
Worst-case interval
Nominal = Σsigned nominal terms
Total bound = Σabsolute bounds
Interval = nominal ± total bound
For 10 ± 0.1 in plus 20 ± 0.2 in, nominal is 30 in and interval is 29.7–30.3 in. For 20 ± 0.2 − (10 ± 0.1), enter 20, .2 and -10, .1; result is 9.7–10.3 in. These bounds follow direct interval addition, without a statistical assumption.
A zero bound leaves that term fixed in the supplied model. Negative bounds, missing values, and malformed rows are rejected; up to 50 rows are supported. Computation uses exact input arithmetic and three-decimal display rounding.
This is a worst-case envelope, not a claim that the extremes occur frequently. It does not account for correlations that can rule out combinations, nonlinear geometry, thermal effects, or unknown tolerances. The stacked thickness tool sums positive measured layers without propagating bounds.