Subtract stated gaps from a defined opening
Use the clear rectangular opening at the plane occupied by the leaves, rather than a nominal frame size, rough opening, or outside frame dimension. The side, top, bottom, and meeting gaps are dimensions you supply from the applicable drawing or project requirements. No standard deductions are assumed.
For one leaf in an opening of width W and height H:
Leaf width = W − left gap − right gap
Leaf height = H − top gap − bottom gap
For two equal leaves, the meeting gap lies between them and is subtracted once:
Each leaf width = (W − left gap − right gap − meeting gap) ÷ 2
The pair mode assumes equal-width leaves and the same height. It does not determine an active/inactive leaf split or add the geometry of an overlapping astragal.
Work through a single leaf and a pair
Take a hypothetical clear opening 36 × 80 in, left and right gaps of 1/8 in each, a 1/8 in top gap, and a 3/4 in bottom gap:
- Width:
36 − 0.125 − 0.125 = 35.750 in, or 908.050 mm. - Height:
80 − 0.125 − 0.75 = 79.125 in, or 2,009.775 mm.
For a 72 in wide opening with the same side gaps and a 1/4 in meeting gap, each equal leaf is (72 − 0.125 − 0.125 − 0.25)/2 = 35.750 in wide. Each leaf plus the gaps must account for the entire stated width; the meeting gap is not charged separately to each leaf.
These numbers demonstrate the dimension chain. They are not recommended door clearances or fire-door allowances.
Zero gaps and impossible deductions
An explicitly entered zero gap is accepted as a geometric boundary. Missing gaps are not silently filled with zero. The opening must exceed the combined deductions in each direction; a zero or negative resulting leaf dimension is rejected.
Changing between one leaf and a pair clears the previous result. The meeting gap is used only for the pair, so an inactive entry cannot alter a single-leaf result. Dimensions remain exact internally and display three decimals with half-up rounding.
Reconcile the result with the assembly drawing
Frame stops, rabbets, bevels, thresholds, floor slope, hardware projections, seals, and astragals can change the relevant dimension references. Establish those references before applying this simple rectangular chain. The tool does not convert a rough opening to a frame opening or approve an undercut, egress width, accessibility condition, or rated assembly.
For a frame that may be out of square, analyze the four measured corners before treating it as a rectangle. For buying linear seals or continuous hardware after the geometry is established, prepare a separate length takeoff. The formulas above follow the stated edge-to-edge dimension chain; length conversion uses the exact unit definitions.