Add measured layers
Add the thickness of each layer in a simple stack. For example, you may need to record a door thickness together with separate plates or spacers before checking a manufacturer’s supported thickness range. Each layer can use inches or millimeters.
Total thickness = layer 1 + layer 2 + … + layer n
Measure the actual stack
Use thickness measured in the same direction for all layers. Add only material that actually contributes along that line. A recessed plate does not necessarily add its full thickness to the finished stack. Gaps, recesses, overlapping material, and compression are not automatically subtracted or modeled.
If the assembled stack can be measured directly, compare that measurement with your arithmetic sum. The sum does not establish usable screw engagement, spindle length, cylinder length, or complete lock compatibility.
Enter and manage layers
Inches accept decimals, simple fractions such as 1/8, and mixed numbers such as 1 3/4. Millimeters accept decimal numbers. Every layer must be greater than zero; remove a layer you do not need instead of leaving it blank.
Use Add layer or a layer’s Remove layer button to change the list. At least one layer remains. The tool supports up to 20 layers to keep the form and result readable; this is a software limit, not an installation rule. Reset restores two blank layers.
Worked example
Start with 1 3/4 in and add 1/8 in. These are hypothetical thicknesses, not a recommended hardware assembly.
The sum is 1.75 + 0.125 = 1.875 in, exactly 47.625 mm. Load example enters these two layers and calculates the total immediately.
Add a third layer
Adding 1/16 in gives 1.875 + 0.0625 = 1.9375 in, exactly 49.2125 mm. At three decimal places the result displays 1.938 in and 49.213 mm. The exact total remains visible separately.
Replacing the first layer with 44.45 mm produces the same physical total. Unit conversion uses the exact relationship 1 in = 25.4 mm before summing, and display rounding occurs only at the end.
Interpret the result
The table records every included layer and its entered unit. The total is an arithmetic thickness, not a check of compression or mounting geometry. Use the dimensional comparison tool if you have an applicable measured-value range from the actual manufacturer.
Three decimal places use half-up rounding. Exact repeating values appear as reduced fractions. Display precision does not create an installation tolerance.
FAQs
Can I mix units in one stack?
Yes. Select the unit for each layer independently. Check each value in its selected unit before calculating; changing a unit does not automatically rewrite the entered number.
Can I subtract a recess?
This tool adds positive measured layers only. Do not enter a negative layer to infer an assembled thickness. Measure the finished stack or use a model that explicitly describes the recess and overlap.
Sources
This tool uses arithmetic addition and the exact inch-to-millimeter relationship described in References. It contains no manufacturer’s thickness allowance or material-compression data. The worked examples are independently checkable sums.