Door opening projection calculator

Calculate the span remaining to an opposite stop after projecting a specified door rectangle across the opening.

Your inputs

Inches accept decimals and fractions. Millimeters accept decimals. Changing units reinterprets the numbers; it does not convert them.

From its left width edge; 0 to leaf width.
From its lower thickness face; 0 to thickness.
Nonnegative.
0–90. Closed leaf width points along +x.

Enter your values or load the labeled example.

Your result

Waiting for your inputs

Your results will appear here after calculation.

One-sided plan projection at 0–90°. The pivot is within the closed leaf rectangle, and its opening-axis offset is nonnegative. The remaining span is measured to the right of the furthest door projection; this is not a complete accessibility or egress check.

A defined projection, with a defined datum

Set the opening datum at the hinge side and the opposite stop to its right. The closed door rectangle occupies x = 0–width, y = 0–thickness in its local system; the pivot lies at local (px, py). Its world x-position is the supplied nonnegative offset from the hinge-side datum. Opening rotates counterclockwise, 0–90°.

Project the furthest door corner

Door projection = axis offset + (width − px) cosθ + py sinθ
Remaining span = max(0, opening span − door projection)

This gives the contiguous span to the right of the full door projection, not a traversal analysis through arbitrary three-dimensional obstructions. At angles below 90°, it uses the full plan projection rather than claiming the prescribed regulatory measurement.

Independent example and measurement context

For a 36 in opening and leaf, thickness 1.75 in, pivot (0,1.75) in, zero axis offset and 90°, the projection is 1.75 in and remaining span 34.25 in. At 0° the same leaf projects 36 in and leaves zero. At 90°, the Access Board describes clear width measurement from the stop to the door face. The actual door face, stop, hardware projections, and required measurement conditions must be checked on the installed assembly.

The tool displays three-decimal numerical results. Pivot coordinates outside the leaf, nonpositive dimensions, or angles above 90° are rejected. It does not issue a width pass/fail, maneuvering-clearance result, or ADA/egress compliance conclusion.