Door actuator stroke calculator

Find pin-to-pin length extremes and geometric stroke for a fixed anchor and a rotating door attachment.

Your inputs

Inches accept decimals and fractions. Millimeters accept decimals. Changing units reinterprets the numbers; it does not convert them.

Signed; same origin at door pivot.
Signed; +y is counterclockwise from +x.
0–180; initial door point is on +x.

Enter your values or load the labeled example.

Your result

Waiting for your inputs

Your results will appear here after calculation.

Two-dimensional ideal pin joints. The moving point starts on +x at the stated radius and rotates counterclockwise from 0 to the final angle. Anchor coordinates are fixed relative to the door pivot. Geometry alone does not establish actuator force, usable stroke, or collision clearance.

Define both attachment points in one plan view

Use this geometric model to compare an attachment layout with a stated actuator stroke. Put the door pivot at the origin. The moving attachment starts at (r, 0) and rotates counterclockwise through 0–180°. Enter the fixed anchor’s signed coordinates in that same plane.

Length over the entire interval

L(θ) = √[(r cos θ − aₓ)² + (r sin θ − aᵧ)²]
Geometric stroke = maximum L − minimum L over the entered interval

This follows the Euclidean distance between the fixed anchor and rotating point. The calculation evaluates both endpoints and every interior extremum where the anchor direction and rotating radius are parallel or antiparallel. Endpoint length difference alone can miss an interior extreme. This is not an angle-sampling approximation.

Example with equal endpoint lengths

Let r = 10 in, fixed anchor (0, 10) in, and final angle 180°. Both endpoint lengths are √200 ≈ 14.142 in. At 90°, the points coincide and length is 0 in, so the interval maximum is 14.142 in, minimum 0, and geometric stroke 14.142 in. The zero-length position flags a physically problematic attachment layout; it is still a defined geometric boundary.

A different anchor at (-10, 0) in over 0–180° gives a maximum 20 in and minimum 0 in. The fixed anchor cannot be the pivot. Lengths round to three decimals after numerical trigonometry.

Geometry does not select an actuator

The model omits actuator body size, articulation limits, interference, force and torque, stops, bending, dynamic effects, and pinch hazards. No real actuator can be approved using stroke alone. The point-swing tool provides the simpler moving-point coordinates; this tool adds a second fixed anchor and interval length extrema.