Compare dimensional response to temperature
A door dimension and a frame dimension can change by different amounts when their materials or temperatures differ. This calculator compares two independently defined free linear dimensional changes. It helps check the arithmetic behind a thermal movement assumption before comparing it with an actual door assembly drawing.
It does not predict an installed door gap. Hinges, anchors, constraints, coatings, composite construction, nonuniform sunlight, and moisture can change the physical response. A door that binds cannot be diagnosed from two expansion coefficients alone.
Define the dimension and its reference temperature
For each object, identify both endpoints of a dimension along the same comparison axis. A door width and an inside frame span are possible records, but the material data must support applying the model to those particular dimensions. An inside frame opening does not necessarily expand like an unconstrained bar of the same nominal span.
Enter each dimension at its own stated reference temperature, its applicable nonnegative linear expansion coefficient, and its final-minus-reference temperature difference. Use the survey sheet to retain endpoints, material or assembly identification, source revision, reference temperature, and constraints. Do not assume the door and frame undergo the same temperature change.
Calculate free linear change
OpenStax, University Physics Volume 2, §1.3 describes the linear approximation:
ΔL = α × L(reference) × ΔT
The coefficient α is always entered per °C, as an ordinary decimal. For example, 12 × 10⁻⁶ per °C is entered as 0.000012, not 12. Values here are examples, not assigned properties of a particular door. Obtain the coefficient and its valid range from material or assembly data. The supported input model accepts zero or positive coefficients; materials requiring a negative coefficient are outside this version.
For Fahrenheit temperature differences, the tool converts Δ°C = Δ°F × 5/9. There is no subtraction of 32 because this is a difference, not an absolute temperature. The coefficient field stays per °C even when the temperature difference uses °F.
Heating gives positive change for a positive coefficient; cooling gives negative change. Zero temperature change or a zero coefficient gives zero dimensional change. Dimensions must remain positive under the stated linear model. This numerical check does not establish that the linear approximation is physically valid for a large temperature excursion.
Interpret frame change minus door change
Relative dimensional change = ΔL(frame) − ΔL(door)
A positive result means the entered frame dimension increases more, or decreases less, than the door dimension. A negative result means the door dimension increases more, or decreases less. It does not specify which edge moves or how that change distributes between two sides.
Only if the frame dimension really represents an independently expanding opening span, and both dimensions follow the assumed free behavior, could their difference describe the change in total span surplus. This tool does not add an initial gap or decide whether an assembly meets clearance, fire-door, or installation requirements. Use door leaf dimensions for a separate stated opening-and-gap dimension chain.
Work through a hypothetical width comparison
Assume two 36 in reference dimensions. Give the door a coefficient of 0.000012 per °C, the frame 0.000024 per °C, and each a 50°C increase. No particular material or product is assigned these example properties.
| Quantity | Independent calculation | Exact result |
|---|---|---|
| Door free change | 36 × 0.000012 × 50 | 0.0216 in = 0.54864 mm |
| Frame free change | 36 × 0.000024 × 50 | 0.0432 in = 1.09728 mm |
| Frame minus door change | 0.0432 − 0.0216 | 0.0216 in = 0.54864 mm |
The relative change displays as 0.022 in and 0.549 mm. These rounded numbers represent the same underlying result; they are not installation tolerances. Equivalent inputs are 914.4 mm reference dimensions or 90°F temperature increases. The same positive coefficients with −50°C changes produce a relative change of −0.0216 in.
Recognize conditions that need a different assessment
The linear model assumes each dimension responds uniformly and freely with an applicable approximately constant coefficient. It excludes moisture swelling in wood, layered construction, thermal gradients, bowing, differential movement along a member, mechanical restraint, and thermal stress. An exterior surface temperature alone may not describe the full door section.
Do not turn this arithmetic result into a universal trimming allowance or an explanation for every seasonal sticking problem. Record actual measurements and environmental conditions, then obtain the relevant assembly guidance. Frame geometry can analyze measured planar corners; dimensional chain bounds can propagate bounds you explicitly supply. Neither substitutes for a verified thermal or moisture model of the installed assembly.