Charge taken from a capacitor causes voltage drop
For a capacitor directly supplying a constant current, charge removal is proportional to time. This simple model can establish a theoretical hold-up baseline at a stated capacitor node. It is different from a battery amp-hour budget or a regulated constant-power load.
Charge and voltage
Removed charge = current × time
Ideal capacitance = current × time / allowed voltage drop
This follows Q = CV. For 0.1 A, 0.1 s, and 1 V allowed decrease, required ideal capacitance is 0.01 F = 10,000 µF. Zero current or zero duration yields zero in this ideal arithmetic; positive voltage drop is still required.
Exact decimal arithmetic precedes three-decimal display. Real hold-up depends on initial voltage, device undervoltage limits, capacitor tolerance, ESR, leakage, aging, temperature, inrush, and any converter’s efficiency/control. This tool does not select a capacitor voltage rating or guarantee a lock/controller’s hold time.