Time to a voltage threshold is not simply RC
A first-order RC node approaches its final voltage exponentially. RC is the time constant, not the time to every possible threshold. This model can help analyze a defined low-voltage timing node; it does not recreate a commercial door-control timer’s circuit.
Initial, final, and threshold voltages
V(t) = Vf + (Vi − Vf)e^(−t/RC)
t = −RC ln[(Vthreshold − Vf)/(Vi − Vf)]
The OpenStax RC-circuit explanation describes exponential charging/discharging and τ = RC. For 1,000 Ω, 1,000 µF, initial 0 V, final 10 V, threshold 5 V, τ is 1 s and crossing time is ln 2 ≈ 0.693 s. Discharging from 10 to 0 through the same R/C reaches 5 V in the same time.
The threshold must be strictly between distinct initial/final voltages. A threshold equal to the asymptotic final voltage has no finite crossing time in this ideal model and is rejected. Resistance and capacitance must be positive; nonnegative voltages are supported. Three-decimal numerical outputs include no tolerance or leakage model.
Real controller timers, debouncing circuits, and electronic inputs may include loading, hysteresis, thresholds, firmware, or additional stages. A product timer’s advertised timing function does not establish that it uses this circuit. Do not infer actual lock release timing or a compliant delay from this result.