Calculate threshold-crossing time for a capacitor approaching a fixed final voltage through a stated resistance.

Your inputs

Use decimal values in the labeled units. Fractions, scientific notation, and missing values are not treated as valid numbers.

Enter your values or load the labeled example.

Your result

Waiting for your inputs

Your results will appear here after calculation.

Single first-order RC transition with constant R and C, no loading or leakage. Threshold lies strictly between distinct initial and final voltages. This is a circuit model, not a lock timer or controller timing guarantee.

Time to a voltage threshold is not simply RC

A first-order RC node approaches its final voltage exponentially. RC is the time constant, not the time to every possible threshold. This model can help analyze a defined low-voltage timing node; it does not recreate a commercial door-control timer’s circuit.

Initial, final, and threshold voltages

V(t) = Vf + (Vi − Vf)e^(−t/RC)
t = −RC ln[(Vthreshold − Vf)/(Vi − Vf)]

The OpenStax RC-circuit explanation describes exponential charging/discharging and τ = RC. For 1,000 Ω, 1,000 µF, initial 0 V, final 10 V, threshold 5 V, τ is 1 s and crossing time is ln 2 ≈ 0.693 s. Discharging from 10 to 0 through the same R/C reaches 5 V in the same time.

The threshold must be strictly between distinct initial/final voltages. A threshold equal to the asymptotic final voltage has no finite crossing time in this ideal model and is rejected. Resistance and capacitance must be positive; nonnegative voltages are supported. Three-decimal numerical outputs include no tolerance or leakage model.

Real controller timers, debouncing circuits, and electronic inputs may include loading, hysteresis, thresholds, firmware, or additional stages. A product timer’s advertised timing function does not establish that it uses this circuit. Do not infer actual lock release timing or a compliant delay from this result.